Technical Specification

SolSlim

When planning a radiant heating installation, refer to Table 1 to select the application and type of environment you wish to heat. Table 2 shows the area that can be heated by a single SolSlim radiant heater in 3kW and 2kW variants.


Table 1 - SolSlim heating index

Applications Heating Index
Offices, canteens, waiting rooms, entrance halls, dressing rooms 10-14
Shops, meeting halls, recreation rooms, clubs 12-16
Workshops, garages, public buildings 14-18
Warehouses, loading bays, hangars 16-20
Churches 18-20


Table 2 - SolSlim heated area

Heating index 3kW 2kW
H L W H L W
10 4.0 5.24 5.49 3.3 4.11 4.53
12 3.6 4.88 4.94 3.0 3.84 4.12
14 3.2 4.51 4.39 2.7 3.57 3.70
16 3.5 4.33 4.12 2.5 3.38 3.43
18 2.8 4.14 3.84 - - -


H = mounting height (determined by on-site requirements) L = length of the heated area W = width of the heated area


Product selector

Model Rating (kW) Height (mm) Width (mm) Depth (mm) Minimum Clearance To Floor (mm) Minimum Clearance To Ceiling (mm) Minimum Clearance To Each Side (mm)
CSL2/SL2* 2 108 1,215 71 2000 300 500
CSL3/SL3* 3 108 1,671 71 2000 300 500


*While stocks last